Zeiss Lenzen
-
AT LISA 809 M
The new generation of high performance multifocal ,diffractive, a-spheric IOL's for micro incision cataract surgery (MICS).
Specifications:
- Material: Hydrophilic acrylic (25%) with hydrophobic surface:
- Optic: 6.0mm
- Total: 11.0mm
- Haptic Angulation: 0
- Lens Design: Single-Piece, diffractive, + 3.75 D, Micro Incision
Click here for the brochure with more information.
-
AT LISA toric 909 M
The world's first multifocal toric a-spherical MICS IOL, that combines excellent performances and reliable astigmatism correction in one IOL.
Specifications:
- Material: Hydrophilic acrylic (25%) with hydrophobic surface:
- Optic: 6.0mm
- Total: 11.0mm
- Haptic Angulation: 0
- Lens Design: Single-Piece, diffractive, + 3.75 D Micro Incision
- Diopter Range: Sphere -10 to +32 Dioptrie, cilinder +1 to +12
Click here for the brochure with more information.
-
AT TORBI 709 M
The first toric IOL for micro-incision cataract surgery that corrects astigmatism to cilinder 12.0 Diopter.
Specifications:
- Material: Hydrophilic acrylic (25%) with hydrophobic surface:
- Optic: 6.0mm
- Total: 11.0mm
- Haptic Angulation: 0
- Lens Design: Single-Piece, bitoric, Micro Incision
- Diopter Range: Sphere -10 to +32 Dioptrie, cilinder +1 to +12
Click here for the brochure with more information.
-
CT ASPHINA 409 M
The first a-spherical IOL for real micro incision cataract surgery (MICS).
Specifications:
- Material: Hydrophilic acrylic (25%) with hydrophobic surface:
- Optic: 6.0mm
- Total: 11.0mm
- Haptic Angulation: 0
- Lens Design: Single-Piece, Micro Incision
Click here for the brochure with more information.
-
CT ASPHINA 409MP + BLUEMIXS™ 180 injector
The first preloaded monofocal IOL with an 1.8mm incision. (MICS)
- Optic design: Monofocal, aspheric (aberration neutral)
- Material: Hydrophilic acrylic (25%) with hydrophobic surface
- Optic: diameter 6.0 mm
- Total: diameter 11.0 mm
- Haptic: angulation 0°
- Lens design: Single-piece, MICS
- Incision size: 1.8 mm
- Company labeled A-constant: 118.0
- Diopter range: From 0.0 to +32.0 D 0.0 to +10.0 D, 1.0 D increments +10.0 to +30.0 D, 0.5 D increments +30.0 to +32.0 D, 1.0 D increments
- ACD: 4.97
- Implantation in: Bag
- Injector/Cartridge Set: BLUEMIXS® 180
--------------------------------------------------------------------------------------
BLUEMIXS™ 180 injector voor preloaded MICS IOL's
The BLUEMIXS® 180 injector
- 1.8 mm incision size
- Safety of preloaded IOLs
- Controlled and linear visco injection
- Astigmatism-neutral surgery with rapid visual recovery
- Covers the complete range of ZEISS preloaded MICS IOLs
The BLUEMIXS® 180 injector is the safe and easy start for micro incision cataract surgery.
Surgeons who have tested the BLUEMIXS® 180 were impressed by how easy and safe the MICS IOL implantation was, using this injector that is especially designed for the MICS procedure.
Click here for the brochure with more information.
-
CT SPHERIS 203 (XL Stabi)
The hydrophilic acrylic I.O.L. of Rockmed is produced by Ioltech, a company of Carl Zeiss Meditec. Also available in the CT Spheris 203P (XL stabi sky), a preloaded lens with the SkyJet injection system.
Details:
- Single-piece Biconvex
- Optic: 6.0 mm
- Total: 10.5 mm
- Loop angle: 10 °
- Factor A: 118
- ACD: 4.96
- Power: from 8 to 30
- Dioptres (from 8 to 25 D per 0.5D)
Click here for the brochure with more information.
-
CT SPHERIS 209 M
A spherial IOL for real micro-incision cataract surgery (MICS).
Specifications:
- Material: Hydrophilic acrylic (25%) with hydrophobic surface:
- Optic: 6.0mm
- Total: 11.0mm
- Haptic Angulation: 0
- Lens Design: Single-Piece, Aspheric, Micro Incision
Click here for the brochure with more information.